Customization: | Available |
---|---|
Appearance: | Water |
Type: | Concrete Admixture |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Technical data sheet | |||
Detection project | Performance index | Measured value | |
Water reducing ratio % | ≥14 | ≥20 | |
Bleeding rate ratio % | ≤90 | ≤80 | |
Gas content % | ≤3.0 | ≤2.0 | |
The gap of condense time (min) | Initial condense | -90~120 | -90~120 |
Final condense | |||
Ratio of compressive strength % | 1d | ≥140 | ≥160 |
3d | ≥130 | ≥150 | |
7d | ≥125 | ≥140 | |
28d | ≥120 | ≥130 | |
Ratio of shrinkage rate % | ≤135 | ≤135 | |
Corrosion effect for steel | None | None | |
Uniformity index | Detection project | FDN Powder Index | |
Solid content (%) | ≥90 | ||
Fitness (%) | 0.315mm (residue)<10 | ||
PH value(10g/L) | 7--9 | ||
Chlorine ion content(%) | ≤0.5 | ||
Sodium sulfate content(%) | ≤5 | ||
Total alkali content(%) | ≤20 | ||
Insoluble matter(%) | ≤0.5 | ||
Cement net fluidity(mm) | ≥220 | ||
Appearance | Yellowish-brown powder | ||
Recommended dosage range of 0.5-0.8%, the user should according to the need to experiment to determine the optimal dosage. |